cdot lif troubleshoot

1. create a lif

net int create -vserver nfs1 -lif tester -role data -data-protocol cifs,nfs,fcache -home-node cl1-01 -home-port e0c -address 1.1.1.1 -netmask 255.0.0.0 -status-admin up

2. go to diag mode
set diag

3. view the owner of the new lif and delete the owner of the new lif
net int ids show -owner nfs1
net int ids delete -owner nfs1 -name tester
net int ids show -owner nfs1

4. run net int show and see that the lif is not there.
net int show

5. try to create the same lif again.
net int create -vserver nfs1 -lif tester -role data -data-protocol cifs,nfs,fcache -home-node cl1-01 -home-port e0c -address 1.1.1.1 -netmask 255.0.0.0 -status-admin up

(this will fail because the lif is still there, but has no owner)

6. debug the vifmgr table
debug smdb table vifmgr_virtual_interface show -role data -fields lif-name,lif-id
(this will show you the node, the lif-id and the lif-name)

7. using the lif-id from the previous output, delete the lif entry.
debug smdb table vifmgr_virtual_interface delete -node cl1-01 -lif-id 1030

8. see that the lif is gone.
debug smdb table vifmgr_virtual_interface show -role data -fields lif-name,lif-id

9. create the lif.
net int create -vserver nfs1 -lif tester -role data -data-protocol cifs,nfs,fcache -home-node cl1-01 -home-port e0c -address 1.1.1.1 -netmask 255.0.0.0 -status-admin up

This entry was posted in Uncategorized. Bookmark the permalink.

Comments are closed.